The OPSA-150 is a new organic pollutant monitor that uses HORIBA's proprietary Rotary Cell Length Modulation, a measuring technique incorporating 25 years of expertise. The unit can be used as an organic pollutant monitor at drainage systems for determining compliance with COD monitoring regulations, for monitoring quality of water measuring levels of organic matter at water supply intakes, and as an organic monitor on process lines (phenol meter)
Measurement items : UV absorbance, VIS absorbance, Converted COD level, Converted TURB level Principle : 2 light path 2 wavelength cell length modulation Measurement wavelength : UV: 253.7 nm, VIS: 546.1 nm Construction of analysis section : Rotary type Range (equivalent to a cell length of 10 mm) : UV absorbance / VIS absorbance. 0 to 0.1 Abs - 0 to 5.0 Abs (Can be set 0.1 Abs increments) Resolution : 0.0001 Abs (Can be set to 0.001 Abs) Repeatability : Within ±2% of full scale (within ±5% if full scale is 2.6 to 5.0 Abs) Linearity : Within ±2% of full scale (within ±5% if full scale is 2.6 to 5.0 Abs) Stability : Within ±2% of full scale in 24 hours (within ±4% in 24 hours if full scale is 2.6 to 5.0 Abs) Response time : T 90 within 1 minute (flow rate of 5 L/min) Cleaning method (cleaning cycle) : Automatic cleaning via wipers (continuous cleaning) Material of parts in contact with sample : SUS, PVC, PP, CR, SiO2 Power source : AC 100 V to AC 230 V ±10%, 50/60 Hz Power consumption : AC 100 V to AC 120 V: 45 VA maximum AC 200 V to AC 230 V: 60 VA maximum Weight : Operating section : Approx. 5.0 kg Analyzer section : Approx. 5.6 kg External dimensions operating section : 240 (W) x 105 (D) x 320 (H)
The Hi98703 meets and exceeds the requirements of the USEPA Method 180.1 for wastewater and Standard Method 2130 B for drinking water. The HI 98703 measures the turbidity of a sample in the 0.00 to 1000 (Nephelometric Turbidity Units) range. An effective algorithm calculates and converts the readings in NTU. The instrument has an EPA compliance reading mode which rounds the reading to meet EPA reporting requirements. Depending on the measured probe and needed accuracy, normal, continuous, or signal averaging measurement can be selected
The Hi98713 is a high accuracy portable turbidity meter. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards used for calibration and performance verification. The Hi98713 meets and exceeds the requirements of the ISO 7027 Method for turbidimetric measurements. The Hi98713 Precision ISO Turbidity Portable Meter is specially designed for water quality measurements, providing reliable and accurate readings, even within low turbidity ranges. The instrument is based on a state-of-the-art optical system which guarantees accurate results, assures long term stability, and minimizes stray light and color interferences
The Hi93414 is a high accuracy Turbidity and Chlorine Portable Meter. This meter is a combination of a nephelometer and photometer to measure the most important parameters in drinking water: turbidity and chlorine. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards and NIST traceable secondary chlorine standards used for calibration and performance verification. The HI93414 meets and exceeds the requirements of EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B for turbidity measurements.The chlorine measurements are are adapted EPA Method 330.5 and Standard Method 4500-Cl G