Product

Cable Diagnostic Tester DC Cable Tester  Megger HV Tester 25
DC Cable Tester – Megger HV Tester 25
The HV Tester 25 kV is a high-voltage generator with a variable negative DC output voltage of 0 - 25 kV. The condition of the test object with regard to electrical strength and insulation quality can be determined on the basis of the unit's readings for output voltage and current. Due to its small size and internal battery this test-system is ideal for test-conditions where no external power supply is available
Rp.123
See Details
Cable Diagnostic Tester DC Cable Tester  Megger T991
DC Cable Tester – Megger T99/1
The high voltage test unit T99/1 is a portable and powerful test device able to generate a DC voltage of up to 40 kV. The T 99/1 is used for testing of cables, cable accessories, plant and installations. Because of the short-circuit proof design and high output current of the T 99/1, this is device is also suitable for cable fault location (in conjunction with a TDR unit)
Rp.123
See Details
Cable Diagnostic Tester DC Cable Tester  Baur PGK25
DC Cable Tester - Baur PGK25
The portable PGK 25 DC HV tester is used for DC voltage testing up to 25 kV of paper-insulated mass-impregnated cables and electrical equipment in the medium-voltage network. The PGK 25 is characterised by its low weight of only 16.5 kg, by its easy operation and by its solid construction for onsite use. The device can be operated via the mains, an integrated rechargeable battery or an external power supply and is therefore suitable for universal use
Rp.123
See Details
Cable Diagnostic Tester DC Cable Tester  Baur PGK50E
DC Cable Tester - Baur PGK50E
The portable, one-piece PGK 50 high-voltage test device for generating negative DC voltage up to 50 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions
Rp.123
See Details
Cable Diagnostic Tester DC Cable Tester  Baur PGK80E
DC Cable Tester - Baur PGK80E
The portable, one-piece PGK 80 high-voltage test device for generating negative DC voltage up to 80 kV is primarily used for onsite testing of paper-insulated mass-impregnated cables in the medium-voltage network. The high voltage is generated through a high-voltage transformer with secondary voltage-multiplier. The internal operating frequency of 20 kHz enables the smallest of device dimensions
Rp.123
See Details
Lube, Oil and Grease Analyzer Oil Tan Delta and Insulating Oil Testing  Baur DTL C
Oil Tan Delta and Insulating Oil Testing - Baur DTL C
The established analysis and diagnostic testing of insulating oils with the BAUR DTL C deliver valuable findings in scientific work, research and development. Extensive knowledge on the current state of insulating materials is gaining importance even for the mains network operator. The BAUR DTL C offers the latest and most precise information for efficient oil management in plants in the electricity and other industries
Rp.123
See Details
Lube, Oil and Grease Analyzer Insulating Oil Testing  Baur DPA75C
Insulating Oil Testing - Baur DPA75C
The BAUR DPA 75 C oil breakdown voltage tester automatically tests the electrical breakdown strength of insulating liquids. Test sequences can be accomplished easily and fully automatically in compliance with all international and national standards. With reliable, informative test results it is possible to determine the exact condition of the insulating material and initiate any necessary measures, e.g. preparation of transformer oil
Rp.123
See Details
Lube, Oil and Grease Analyzer Insulating Oil Testing  Baur DTA 100 C
Insulating Oil Testing – Baur DTA 100 C
The BAUR DTA 100 C oil tester is designed for continuous operation in the laboratory and is characterised by the combination of extraordinary features. As a high-performance device with a test voltage up to 100 kV, with clear breakdown detection and absolutely reliable measurement results even across several measurement sequences, the BAUR DTA 100 C is the leading testing device for users in the electricity and other industries and in testing institutes
Rp.123
See Details
Lube, Oil and Grease Analyzer Insulating Oil Testing  Baur DTA IL
Insulating Oil Testing – Baur DTA IL
The BAUR DTA Inline is a high performance and reliable oil tester for continuous testing of the breakdown strength of insulating oils during production (inline tests). The combination of extremely short switch-off times during breakdowns and the easy oil sample handling facilitate high quality statements and conclusions on the insulating oil quality
Rp.123
See Details
Power Meter and Process Calibrator Surge Voltage Generator  Baur SSG1100
Surge Voltage Generator - Baur SSG1100
Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver
Rp.123
See Details
Power Meter and Process Calibrator Surge Voltage Generator  Baur SSG1500
Surge Voltage Generator - Baur SSG1500
Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver
Rp.123
See Details
Power Meter and Process Calibrator Surge Voltage Generator  Baur SSG2100
Surge Voltage Generator - Baur SSG2100
Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver
Rp.123
See Details