Ultra-compact sound meter meets class 2 standards with ±1dB high accuracy that allows for quick and reliable sound level testing. It features a large backlit display for easy viewing and measures A & C weighting from 35 to 130dB with Fast and Slow response time mode. Size is small enough to conveniently fit in your pocket and includes a wrist strap
Tanaka MPC102S has been desined for automatic determination of pour point (PP) and cloud point (CP) with small specimen size and shorter test cycle time while securing better test precision than the conventional manual methods. PP measurement is by air pressure method (ASTM D6749) and CP measurement is by small test jar method (ASTM D7683)
Tanaka MPC602 has been designed for automatic determination of POUR POINT (PP) and CLOUD POINT (CP) with small specimen size and shorter test cycle time while securing better test precision than the conventional manual methods. PP measurement is by "AIR PRESSURE METHOD" (ASTM D6749), and CP measurement is by "SMALL TEST JAR METHOD" (ASTM D7683). The epoch-making automatic PP test method yields 1°C test resolution, while the new CP method yields 0.1°C resolution
AVP-30D automatically measures Reid vapor pressure (RVP) utilizing a miniaturized bomb. While ease of operation and smaller instrument size are achieved with the smaller size bombs, test result precisely agrees with that of the regular size Reid bomb
ACR-M3 is a tester to be used for the determination of the amount of carbon residue formed after evaporation and pyrolysis of petroleum material under certain conditions and is intended to provide some indication of the relative coke forming tendency of such materials. Micro Method offers advantages of better control of test conditions, smaller samples, and less operator attention compared to Conradson Carbon Residue test to which it is equivalent
ACR-6 automates the evaporation process of the amount of carbon residue left after evaporation and pyrolysis of an oil. The carbon residue test is intended to provide some indication of relative coke-forming propensities. The microprocessor controlled oven requires less experience to conduct the tedious process and therefore yields more consistent test result
The model AFP-102 automatically executes the Cold Filter Plugging Point (CFPP) test method prescribed in IP309, ASTM D6371 and JIS K2288. After developing its predecessor models, this third generation model has been developed by applying Tanaka’s latest technologies and the various know-hows. “Ease of operation” has been further improved on this model
Tanaka AAP6 automatically determines aniline point for wide range of samples. The use of special infrared detector gives the instrument it's ability to see through dark / opaque samples such as power generation fuels and marine diesel oils. The measuring cell can be easily removed and placed on an analytical balance for weighing viscous samples which are solid at ambient temperature. The measuring cell can be cleaned without disassembling, which makes the cleaning easier and safer
Tanaka AKV-202 has been designed for automatic determination of Kinematic Viscosity. Once sample is set, the series of process including timing, cleaning/drying, and reporting are fully automated. AKV-202 is an economical bench top system which saves not only the technicians' time but also valuable laboratory floor space
The Hi96700 Ammonia Low Range Photometer combines accuracy and ease of use in an ergonomic, portable design. A user can accurately determine the concentration of ammonia (as NH3-N) in freshwater samples within a 0.00 to 3.00 mg/L (ppm) range using the HI93700-0 ready made reagents. The HI96700 offers many advanced features including the exclusive CAL Check function used for performance verification and calibration of the meter
The Hi96715 Ammonia Medium Range Photometer combines accuracy and ease of use in an ergonomic, portable design. Using the Hi93715-0 ready made reagents a user can accurately determine the concentration of ammonia nitrogen (NH3-N) in freshwater samples within a 0.00 to 9.99 mg/L (ppm) range. The Hi96715 offers many advanced features including the exclusive CAL Check™ function used for performance verification and calibration of the meter
The Hi96733 portable photometer is for the measurement of ammonium in freshwater samples. Hanna's portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made standards traceable to a NIST Standard for performance verification and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length